Event params object can be converted to inspector protocol directly.
This also enables binary data, like `Network.dataReceived`, to be sent
in the inspector protocol from JavaScript since JSON representation
does not support plain binary data.
PR-URL: https://github.com/nodejs/node/pull/57027
Reviewed-By: Kohei Ueno <kohei.ueno119@gmail.com>
`StringUtil::CharacterCount` should return the length of underlying
representation storage of a protocol string.
`StringUtil::CharacterCount` is only used in DictionaryValue
serialization. Only `Network.Headers` is an object type, represented
with DictionaryValue.
PR-URL: https://github.com/nodejs/node/pull/56788
Reviewed-By: James M Snell <jasnell@gmail.com>
Reviewed-By: Yagiz Nizipli <yagiz@nizipli.com>
Reviewed-By: Daniel Lemire <daniel@lemire.me>
Reviewed-By: Kohei Ueno <kohei.ueno119@gmail.com>
`NodeRuntime.waitingForDebugger` is a new Inspector Protocol event that
will fire when the process being inspected is waiting for the debugger
(for example, when `inspector.waitForDebugger()` is called). This allows
inspecting processes to know when the inspected process is waiting for a
`Runtime.runIfWaitingForDebugger` message to resume execution. It allows
tooling to resume execution of the inspected process as soon as it deems
necessary, without having to guess if the inspected process is waiting
or not, making the workflow more deterministic. With a more
deterministic workflow, it is possible to update Node.js core tests to
avoid race conditions that can cause flakiness. Therefore, tests were
also changed as following:
* Remove no-op Runtime.runIfWaitingForDebugger from tests that don't
need it
* Use NodeRuntime.waitingForDebugger in all tests that need
Runtime.runIfWaitingForDebugger, to ensure order of operations is
predictable and correct
* Simplify test-inspector-multisession-ws
There might be value in adding `NodeWorker.waitingForDebugger` in a
future patch, but as of right now, no Node.js core inspector tests using
worker threads are not failing due to race conditions.
Fixes: https://github.com/nodejs/node/issues/34730
PR-URL: https://github.com/nodejs/node/pull/51560
Reviewed-By: Benjamin Gruenbaum <benjamingr@gmail.com>
Reviewed-By: Franziska Hinkelmann <franziska.hinkelmann@gmail.com>
Reviewed-By: Joyee Cheung <joyeec9h3@gmail.com>
Add missing initialization reported by coverity. With
proper usage it looks like it will be initialized but
still good to have it initialized to a known state in
case that changes or invalide usage.
The method used to create object ids newObjectId() starts
at 1 so initializing to 0 should be safe and what we get
now when compiled in a way that auto initializes (for example
debug)
Signed-off-by: Michael Dawson <mdawson@devrus.com>
PR-URL: https://github.com/nodejs/node/pull/43254
Reviewed-By: Darshan Sen <raisinten@gmail.com>
Reviewed-By: Minwoo Jung <nodecorelab@gmail.com>
Reviewed-By: Luigi Pinca <luigipinca@gmail.com>
This simplifies the code significantly, and removes the dependency of
the inspector code on the availability of a `MultiIsolatePlatform`
(by removing the dependency on a platform altogether).
It also fixes a memory leak that occurs when `RequestInterrupt()`
is used, but the interrupt handler is never called before the Isolate
is destroyed.
One downside is that this leads to a slight change in timing, because
inspector messages are not dispatched in a re-entrant way. This means
having to harden one test to account for that possibility by making
sure that the stack is always clear through a `setImmediate()`.
This does not affect the assertion made by the test, which is that
messages will not be delivered synchronously while other code is
executing.
https://github.com/nodejs/node/issues/32415
PR-URL: https://github.com/nodejs/node/pull/32523
Reviewed-By: Matheus Marchini <mat@mmarchini.me>
Reviewed-By: James M Snell <jasnell@gmail.com>
Turn tasks scheduled on the `v8::Isolate` or on the given platform
into no-ops if the underlying `MainThreadInterface` has gone away
before the task could be run (which would happen when the
`Environment` instance and with it the `inspector::Agent` instance
are destroyed).
This addresses an issue that Electron has been having with
inspector support, and generally just seems like the right thing
to do, as we may not fully be in control of the relative timing
of Environment teardown, platform tasksexecution, and the
execution of `RequestInterrupt()` callbacks (although
the former two always happen in the same order in our own code).
PR-URL: https://github.com/nodejs/node/pull/30031
Reviewed-By: Eugene Ostroukhov <eostroukhov@google.com>
Reviewed-By: Shelley Vohr <codebytere@gmail.com>
Reviewed-By: Ben Noordhuis <info@bnoordhuis.nl>
- Split the initialization of the inspector and other diagnostics
into `Environment::InitializeInspector()` and
`Environment::InitializeDiagnostics()` - these need to be
reinitialized separately after snapshot deserialization.
- Do not store worker url alongside the inspector parent handle,
instead just get it from the handle.
- Rename `Worker::profiler_idle_notifier_started_` to
`Worker::start_profiler_idle_notifier_` because it stores
the state inherited from the parent env to use for initializing
itself.
PR-URL: https://github.com/nodejs/node/pull/27539
Reviewed-By: Anna Henningsen <anna@addaleax.net>
NodeRuntime domain was introduced to give inspector client way to
fetch captured information before Node process is gone. We need
similar capability for work.
With current protocol inspector client can force worker to wait
on start by passing waitForDebuggerOnStart flag to NodeWorker.enable
method. So client has some time to setup environment, e.g. start
profiler. At the same time there is no way to prevent worker from
being terminated. So we can start capturing profile but we can not
reliably get captured data back.
This PR implemented NodeRuntime.notifyWhenWaitingForDisconnect
method for worker. When NodeRuntime.waitingForDisconnect notification
is enabled, worker will wait for explicit NodeWorker.detach call.
With this PR worker tooling story is nicely aligned with main thread
tooling story. The only difference is that main thread by default is
waiting for disconnect but worker thread is not waiting.
Issue: https://github.com/nodejs/node/issues/27677
PR-URL: https://github.com/nodejs/node/pull/27706
Reviewed-By: Eugene Ostroukhov <eostroukhov@google.com>
Historically Node process sends Runtime.executionContextDestroyed
with main context as argument when it is finished.
This approach has some disadvantages. V8 prevents running some
protocol command on destroyed contexts, e.g. Runtime.evaluate
will return an error or Debugger.enable won't return a list of
scripts.
Both command might be useful for different tools, e.g. tool runs
Profiler.startPreciseCoverage and at the end of node process it
would like to get list of all scripts to match data to source code.
Or some tooling frontend would like to provide capabilities to run
commands in console when node process is finished to allow user to
inspect state of the program at exit.
This PR adds new domain: NodeRuntime. After
NodeRuntime.notifyWhenWaitingForDisconnect is enabled by at least one
client, node will send NodeRuntime.waitingForDebuggerToDisconnect
event instead of Runtime.executionContextDestroyed. Based on this
signal any protocol client can capture all required information and
then disconnect its session.
PR-URL: https://github.com/nodejs/node/pull/27600
Reviewed-By: Eugene Ostroukhov <eostroukhov@google.com>
Reviewed-By: Rich Trott <rtrott@gmail.com>