mirror of
https://github.com/nodejs/node.git
synced 2026-11-24 21:50:36 -05:00
test: deflake test-worker-eventlooputil
worker.performance.eventLoopUtilization() reads the worker's idle time before the current time. If the parent thread stalls between the two reads while the worker is idle, the stall is counted as worker active time in the first sample and is missing from the delta, so the 50ms spin can be reported as slightly less than 50ms. Bound that skew by timing the first workerELU() call. Signed-off-by: Matteo Collina <hello@matteocollina.com> PR-URL: https://github.com/nodejs/node/pull/67260 Refs: https://github.com/nodejs/reliability/issues/1482 Reviewed-By: Robert Nagy <ronagy@icloud.com> Reviewed-By: Ulises Gascón <ulisesgascongonzalez@gmail.com>
This commit is contained in:
1 parent
2b50db1364
commit
5ac48a96db
1 file changed
+7
-1
@@ -95,13 +95,19 @@ function checkWorkerIdle(wElu) {
|
||||
}
|
||||
|
||||
function checkWorkerActive() {
|
||||
// Reading the worker's ELU from this thread is not atomic: the worker's idle
|
||||
// time is read before the current time. If this thread stalls between the
|
||||
// two reads while the worker is idle, the stall is counted as worker active
|
||||
// time in `w` and then missing from `w2`. The duration of the call bounds it.
|
||||
const start = performance.now();
|
||||
const w = workerELU();
|
||||
const skew = performance.now() - start;
|
||||
|
||||
metricsCh.port2.postMessage({ cmd: 'spin', dur: 50 });
|
||||
metricsCh.port2.once('message', mustCall((wElu) => {
|
||||
const w2 = workerELU(w);
|
||||
|
||||
assert.ok(w2.active >= 50, `${w2.active} < 50`);
|
||||
assert.ok(w2.active >= 50 - skew, `${w2.active} < 50 - ${skew}`);
|
||||
assert.ok(wElu.active >= 50, `${wElu.active} < 50`);
|
||||
assert.ok(idleActive(wElu) < idleActive(w2),
|
||||
`${idleActive(wElu)} >= ${idleActive(w2)}`);
|
||||
|
||||
Reference in new issue
Block a user