src: make WaitForInspectorDisconnect an exit hook

Run inspector cleanup code on Environment teardown.

This is part of a series of changes to make embedding easier, by
requiring fewer internal methods to build a fully functioning
Node.js instance.

PR-URL: https://github.com/nodejs/node/pull/30229
Reviewed-By: Colin Ihrig <cjihrig@gmail.com>
Reviewed-By: Gireesh Punathil <gpunathi@in.ibm.com>
Reviewed-By: Joyee Cheung <joyeec9h3@gmail.com>
Reviewed-By: Shelley Vohr <codebytere@gmail.com>
This commit is contained in:
Anna Henningsen authored and Myles Borins committed 2019-11-16 23:59:09 -08:00
1 parent cd233e3f16
commit db7deb6e7a
6 files changed
+26 -47

No files matched your search

+7
View File
@@ -778,6 +778,13 @@ bool Agent::Start(const std::string& path,
StartDebugSignalHandler();
}
AtExit(parent_env_, [](void* env) {
Agent* agent = static_cast<Environment*>(env)->inspector_agent();
if (agent->IsActive()) {
agent->WaitForDisconnect();
}
}, parent_env_);
bool wait_for_connect = options.wait_for_connect();
if (parent_handle_) {
wait_for_connect = parent_handle_->WaitForConnect();
+1 -25
View File
@@ -162,31 +162,6 @@ bool v8_is_profiling = false;
struct V8Platform v8_platform;
} // namespace per_process
#ifdef __POSIX__
static const unsigned kMaxSignal = 32;
#endif
void WaitForInspectorDisconnect(Environment* env) {
#if HAVE_INSPECTOR
if (env->inspector_agent()->IsActive()) {
// Restore signal dispositions, the app is done and is no longer
// capable of handling signals.
#if defined(__POSIX__) && !defined(NODE_SHARED_MODE)
struct sigaction act;
memset(&act, 0, sizeof(act));
for (unsigned nr = 1; nr < kMaxSignal; nr += 1) {
if (nr == SIGKILL || nr == SIGSTOP || nr == SIGPROF)
continue;
act.sa_handler = (nr == SIGPIPE) ? SIG_IGN : SIG_DFL;
CHECK_EQ(0, sigaction(nr, &act, nullptr));
}
#endif
env->inspector_agent()->WaitForDisconnect();
}
#endif
}
#ifdef __POSIX__
void SignalExit(int signo, siginfo_t* info, void* ucontext) {
ResetStdio();
@@ -553,6 +528,7 @@ inline void PlatformInit() {
CHECK_EQ(err, 0);
#endif // HAVE_INSPECTOR
// TODO(addaleax): NODE_SHARED_MODE does not really make sense here.
#ifndef NODE_SHARED_MODE
// Restore signal dispositions, the parent process may have changed them.
struct sigaction act;
+4 -1
View File
@@ -90,7 +90,6 @@ void PrintCaughtException(v8::Isolate* isolate,
v8::Local<v8::Context> context,
const v8::TryCatch& try_catch);
void WaitForInspectorDisconnect(Environment* env);
void ResetStdio(); // Safe to call more than once and from signal handlers.
#ifdef __POSIX__
void SignalExit(int signal, siginfo_t* info, void* ucontext);
@@ -321,6 +320,10 @@ void StartProfilers(Environment* env);
}
#endif // HAVE_INSPECTOR
#ifdef __POSIX__
static constexpr unsigned kMaxSignal = 32;
#endif
bool HasSignalJSHandler(int signum);
#ifdef _WIN32
+14 -1
View File
@@ -152,13 +152,26 @@ int NodeMainInstance::Run() {
env->set_trace_sync_io(false);
exit_code = EmitExit(env.get());
WaitForInspectorDisconnect(env.get());
}
env->set_can_call_into_js(false);
env->stop_sub_worker_contexts();
ResetStdio();
env->RunCleanup();
// TODO(addaleax): Neither NODE_SHARED_MODE nor HAVE_INSPECTOR really
// make sense here.
#if HAVE_INSPECTOR && defined(__POSIX__) && !defined(NODE_SHARED_MODE)
struct sigaction act;
memset(&act, 0, sizeof(act));
for (unsigned nr = 1; nr < kMaxSignal; nr += 1) {
if (nr == SIGKILL || nr == SIGSTOP || nr == SIGPROF)
continue;
act.sa_handler = (nr == SIGPIPE) ? SIG_IGN : SIG_DFL;
CHECK_EQ(0, sigaction(nr, &act, nullptr));
}
#endif
RunAtExit(env.get());
per_process::v8_platform.DrainVMTasks(isolate_);
-1
View File
@@ -433,7 +433,6 @@ static void DebugEnd(const FunctionCallbackInfo<Value>& args) {
static void ReallyExit(const FunctionCallbackInfo<Value>& args) {
Environment* env = Environment::GetCurrent(args);
RunAtExit(env);
WaitForInspectorDisconnect(env);
int code = args[0]->Int32Value(env->context()).FromMaybe(0);
env->Exit(code);
}
-19
View File
@@ -42,17 +42,6 @@ using v8::Value;
namespace node {
namespace worker {
namespace {
#if HAVE_INSPECTOR
void WaitForWorkerInspectorToStop(Environment* child) {
child->inspector_agent()->WaitForDisconnect();
child->inspector_agent()->Stop();
}
#endif
} // anonymous namespace
Worker::Worker(Environment* env,
Local<Object> wrap,
const std::string& url,
@@ -251,9 +240,6 @@ void Worker::Run() {
Locker locker(isolate_);
Isolate::Scope isolate_scope(isolate_);
SealHandleScope outer_seal(isolate_);
#if HAVE_INSPECTOR
bool inspector_started = false;
#endif
DeleteFnPtr<Environment, FreeEnvironment> env_;
OnScopeLeave cleanup_env([&]() {
@@ -283,10 +269,6 @@ void Worker::Run() {
env_->stop_sub_worker_contexts();
env_->RunCleanup();
RunAtExit(env_.get());
#if HAVE_INSPECTOR
if (inspector_started)
WaitForWorkerInspectorToStop(env_.get());
#endif
// This call needs to be made while the `Environment` is still alive
// because we assume that it is available for async tracking in the
@@ -344,7 +326,6 @@ void Worker::Run() {
env_->InitializeDiagnostics();
#if HAVE_INSPECTOR
env_->InitializeInspector(inspector_parent_handle_.release());
inspector_started = true;
#endif
HandleScope handle_scope(isolate_);
InternalCallbackScope callback_scope(